SERVICING INSTRUCTIONS
FAULT FINDING
31
EVIDENCE OF FAULT CAUSE
Burner goes out after burning 1-2 hours
1. Too little primary air
2.Downdraughtintheue.Fitsuitableanti-downdraughtcowl
3.Lowrescrewsettoolow
4. Control metering stem slot obstructed. To clean, turn Control
Knob OFF to full ON several times
5. Fuel inlet blocked. Service
6. Oil depth in burner base too shallow
7. Oil level in tank too low
8. Air lock in oil line tank - burner - control
9. Incorrect or contaminated fuel. A small amount of contamination
cancausetrouble.Cleanouttankandrellwithanewfuel.
10.OilControlvalveoodedandInletValveclosed
Burner goes out for no apparent reason 1. Too little primary air
2.Downdraughtinue.Fitsuitableanti-downdraughtcowl
3. Flue partly or fully blocked
4.Lowrescrewsettoolow
5. Control metering stem slot obstructed. To clear, turn Control
Knob from OFF to full ON several times
6. Trip lever operated
7. Oil Control Filer blocked. Remove and clean with boiling water
and dry thoroughly before replacing.
8. Fuel inlet blocked. Service.
9. Oil level in tank too low.
10. Air lock in oil line tank - burner - control
11. Incorrect or contaminated fuel. A small amount of contamina-
tioncancausetrouble.Cleanouttankandrellwithanewfuel
12.OilControlvalveoodedandInletValveclosed
Burner soots up 1. Too little primary air
2.Toolowauepull
3.Downdraughtinue.Fitsuitableanti-downdraughtcowl
4. Vaporizing Chamber Lid not fully seated
5. Shells not correctly seated
6. Incorrect or contaminated fuel. A small amount of contamina-
tioncancausetrouble.Cleanouttankandrellwithanewfuel.
COOKERS
Not reaching required temperature
1. Too little primary air
2.Toohighauepull
3. Flue partly or fully blocked
4.Highrescrewsettoolow
Overheating 1.Toolowauepull
2.Lowrescrewsettoohigh
Variations in temperature 1.Variationsinuedraught.Fitsuitablestabilizer.
Commentaires sur ces manuels