INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
14
6. WIND PRESSURE ON BUILDINGS
6.1 Flues should not be terminated in a high pressure area.
7. TERMINATIONS
7.1 The most appropriate cowl depends entirely on conditions at
the site. Several may have to be tried before one is found
that gives good all-year performance. In some circumstances
it may not be possible to entirely exclude down draughts
caused by surrounding buildings or trees, so fit an anti-down
draught cowl, preferably of the OH type. A ‘Chinaman’s Hat’
is not sufficient and a GC 1 type cowl must not be fitted.
OH Ltd. Telephone Number 01223 291222
2
Anti-down
draught cowl
Cement mortar
Plate clamp
Brick chimney
Stainless steel
flexible flue
liner
Seal liner into
flue socket with
fire cement
Conventional brick chimney with liner
Back fill with
Vermiculite insulation
or similar
Bends must be no less than
135
o
Vitreous enamelled steel or
stainless steel with cleaning
cover
MIN RISE BEFORE
BEND = 600mm
MIN EFFECTIVE HEIGHT = 3M
AR1580