PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCE
For use in GB and IE
Installation
Instructions
XT - Oil (K P/F)
10/13 EINS 514137[email protected]
DESN 514112 B
Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform the safety and
performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised
by AGA.
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - XT - Oil (K P/F)

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCEFor use in GB and IEInstallationInstructionsXT - Oil (K P/F)10/13 EINS 514137raywarrant

Page 2 - Contents

FLUE DIRECTION - EXIT TO THE RIGHTFollow previous instructions in FLUE SYSTEM, Steps 1 to3.4. Reposition the flexible tube from the oven vent down the

Page 3 - Consumer Protection

The flue system used on this appliance must be providedby AGA and must be installed in accordance with theinstructions and standards.A maximum flue of

Page 4 - TECHNICAL DATA

Site requirements - Flue terminal locationFIG. 12 - Location of flue terminalA DIRECTLY BELOW AN OPENING, AIR 600mmBRICK, OPENING WINDOW etc.B HORIZON

Page 5

The appliance can only be installed in a room whichmeets the ventilation regulations in force. But, in anyevent the room must have a permanent vent of

Page 6

Wiring external to the appliance must be installed inaccordance with current National Wiring Regulations andany local regulations which apply. The app

Page 7

The appliance is floor mounted. The space in which theappliance is to be fitted must have the following minimumdimensions.Between wall or unit and LH

Page 8

1. Check that the hearth is level, then remove the appliance from its transit wooden pallet, and position itwith its back against the wall and in its

Page 9

1. Cut out card template from packaging and affix to wall.2. Cut ø60mm hole in the wall for the flue pipe (See Fig.16).3. Drill 4 wall fixing holes th

Page 10 - Site requirements

18Installation RequirementsFIG. 20EXTERNAL CONNECTIONS : FAN CONNECTIONS - AT TERMINALMAINS CONNECTIONSPCB CONNECTIONS

Page 11

19NOTE: SMOKE/SMELL EMITTED DURING INITIALUSAGE.During Initial usage of operation of the cooker,smoke/smell may be emitted and is normal and not a fau

Page 12

ContentsSECTION CONTENTS PAGECONSUMER PROTECTION 3HEALTH & SAFETY 3TECHNICAL DATA 4SITE REQUIREMENTS INTRODUCTION 5REGULATIONS 5LOCATION 5OIL PIPE

Page 13

Checks to ensure electrical safety should be carried outby a competent person.IMPORTANT NOTE: This appliance is fitted with anoverheat thermostat whic

Page 14

21This thermostat is a safety cut-out device which willoperate under adverse wind or a blocked flue condition.It is a manually reset device which can

Page 15 - Installation requirements

22SEE FIG.25 & 26The air control of the burner is factory pre-set, howeversmall adjustments may be necessary to suit the siteconditions.IMPORTANT:

Page 16

Before leaving the site, check that the operation of cookertimer and thermostat are capable of controlling the burnercorrectly. Check the operation o

Page 17 - Installation Requirements

24Wiring DiagramFIG. 27WIRING DIAGRAM - APPLIANCE

Page 18

Single Channel Programmer USING A SINGLE CHANNEL OPTIONAL PROGRAMMER IN CONJUNCTIONWITH THE RAYBURN 400K PX (P/F) ONLY1. Always use the same isolating

Page 21

28For further advice or information contactyour local distributor/stockistWith AGA Rangemaster’s policy of continuousproduct improvement, the Company

Page 22

Consumer ProtectionAs responsible manufacturers we take care to make sure that our products are designed andconstructed to meet the required safety st

Page 23

4Oil Inlet R1/4 (1/4” BSP Taper Ext)Electrical Supply 230V ~ 50Hz 3 amp FusedPower Flue to 54mm St/St Piperight or leftCO2% - COOKER 11.0Smoke 0 - 1F

Page 24 - Wiring Diagram

The Rayburn is a floor standing cooker, fired by apressure jet oil burner. IMPORTANTl This appliance must only be used with Kerosene Class C2 Complyi

Page 25 - Single Channel Programmer

SEE FIG 2 & 3The oil supply connection between the storage tank andthe oil pipe should be run in copper or steel pipe with aminimum diameter of 10

Page 26

Site requirements7DESN 514167 CDESN 514169 BFIG. 2MAXIMUMLENGTH(METRES)H METRES10mm OD0100-3.0100-3.588-4.040Single Pipe oil systemTwo Pipe oil system

Page 27

Site requirements8FIG. 3FIG. 4DESN 514168 BDESN 511449ONE & TWO PIPE SYSTEMSSEE FIG. 4The cooker as delivered is ready to be used on a one pipesys

Page 28

The flue can be to the left or right of the appliance. Thecooker is supplied with the flue pipe to the left, this can beadjusted to suit the installat

Commentaires sur ces manuels

Pas de commentaire